Skip to Main Content

Incident Search

COGIS - Mechanical Integrity Test Report
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-103-08704CHEVRON FEE
130X
SCOUT ENERGY MANAGEMENT LLC
10779
AC
6/1/2023
RANGELY
72370
RIO BLANCO  103
NWNW 20 2N102W 6
315559View Related Related
 
Form 21View Related Related View DocsDoc
Date Submitted:6/22/2023MIT Assigned By:
Date Recv'd:6/22/2023Facility ID: 
DocNum:403442766Facility Status:
Operator Information:
Oper. No.10779
Operator:SCOUT ENERGY MANAGEMENT LLC
Address:13800 MONTFORT DRIVE SUITE 100  DALLAS  TX 75240
Type Of Facility:Well Status: 
Facility NameCHEVRON FEE
Operator contact:Anita  Sanford
Location:  qtrqtr:  section:  township:  range:  meridian: 
MIT Details:
Test Type:SI/TA MAINTENANCE STATUS
Test Date:6/21/2023
Field Rep:Burchett, Kirby
Approved Date:7/6/2023
Approved by:
Last Approved MIT:6/4/2018
Injection/Producing Formation Zones:WEBR
Perforation Interval:6124-6467
Open Hole Interval:
Bridge/Cement Plug Depth:
Tubing Size:2.875
Tubing Depth:5956
Top Packer Depth:5918
Multiple Packers:
 
Condition of approval:
Test Data:Wellbore Channel Test:
Reading TypePressure
10 MIN CASE359
5 MIN CASE360
FINAL CASE358
FINAL TUBE50
INITIAL TUBE50
LOSS OR GAIN-5
START CASE363
No channel test.