Skip to Main Content

Incident Search

COGIS - Mechanical Integrity Test Report
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-103-05632UNION PACIFIC
4-29
SCOUT ENERGY MANAGEMENT LLC
10779
IJ
4/18/2022
RANGELY
72370
RIO BLANCO  103
NESW 29 2N102W 6
314404View Related Related
 
Form 21View Related Related View DocsDoc
Date Submitted:2/14/2023MIT Assigned By:
Date Recv'd:2/14/2023Facility ID: 
DocNum:403320088Facility Status:
Operator Information:
Oper. No.16700
Operator:CHEVRON USA INC
Address:760 HORIZON DRIVE STE 401  GRAND JUNCTION  CO 81506
Type Of Facility:Well Status: 
Facility NameUNION PACIFIC
Operator contact:Anita  Sanford
Location:  qtrqtr:  section:  township:  range:  meridian: 
MIT Details:
Test Type:5-YEAR UIC TEST
Test Date:2/10/2023
Field Rep:Browning, Chuck
Approved Date:2/14/2023
Approved by:
Last Approved MIT:5/4/2018
Injection/Producing Formation Zones:WEBR
Perforation Interval:5637-6282
Open Hole Interval:
Bridge/Cement Plug Depth:
Tubing Size:2.875
Tubing Depth:5632
Top Packer Depth:5389
Multiple Packers:
 
Condition of approval:
Test Data:Wellbore Channel Test:
Reading TypePressure
10 MIN CASE1250
5 MIN CASE1250
FINAL CASE1250
FINAL TUBE1860
INITIAL TUBE1860
START CASE1250
No channel test.