WELL05-103-11464UNION PACIFIC
153X16
SCOUT ENERGY MANAGEMENT LLC
10779
IJ
5/1/2023
RANGELY
72370
RIO BLANCO  103
NWSW 16 2N102W 6
398839View Related Related
 
Form 21View Related Related View DocsDoc
Date Submitted:11/18/2022MIT Assigned By:
Date Recv'd:11/18/2022Facility ID: 
DocNum:403234587Facility Status:
Operator Information:
Oper. No.16700
Operator:CHEVRON USA INC
Address:760 HORIZON DRIVE STE 401  GRAND JUNCTION  CO 81506
Type Of Facility:Well Status: 
Facility NameUNION PACIFIC
Operator contact:Anita  Sanford
Location:  qtrqtr:  section:  township:  range:  meridian: 
MIT Details:
Test Type:VERIFICATION OF REPAIRS
Repair Type:
Repair Desc:Pull packers and tubing, clean out open hole to 6775 ft. Acid job, run packers and new FL tubing.
Test Date:11/17/2022
Field Rep:Browning, Chuck
Approved Date:11/21/2022
Approved by:
Last Approved MIT:4/6/2018
Injection/Producing Formation Zones:WEBR
Perforation Interval:
Open Hole Interval:6539-6775
Bridge/Cement Plug Depth:
Tubing Size:2.875
Tubing Depth:6520
Top Packer Depth:6433
Multiple Packers:
 
Condition of approval:
Test Data:Wellbore Channel Test:
Reading TypePressure
10 MIN CASE1250
5 MIN CASE1250
FINAL CASE1250
START CASE1250
No channel test.