Skip to Main Content

Incident Search

COGIS - Mechanical Integrity Test Report
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-103-08028FEE
112X
SCOUT ENERGY MANAGEMENT LLC
10779
IJ
4/30/2024
RANGELY
72370
RIO BLANCO  103
NWSE 19 2N102W 6
315174View Related Related
 
Form 21View Related Related View DocsDoc
Date Submitted:9/3/2020MIT Assigned By:
Date Recv'd:9/3/2020Facility ID: 
DocNum:402482085Facility Status:
Operator Information:
Oper. No.16700
Operator:CHEVRON USA INC
Address:100 CHEVRON ROAD  RANGELY  CO 81648
Type Of Facility:Well Status: 
Facility NameFEE
Operator contact:ANITA  SANFORD
Location:  qtrqtr:  section:  township:  range:  meridian: 
MIT Details:
Test Type:5-YEAR UIC TEST
Test Date:9/1/2020
Field Rep:Browning, Chuck
Approved Date:9/14/2020
Approved by:
Last Approved MIT:4/13/2016
Injection/Producing Formation Zones:WEBR
Perforation Interval:5844-6531
Open Hole Interval:
Bridge/Cement Plug Depth:
Tubing Size:2.875
Tubing Depth:5700.9
Top Packer Depth:5614.4
Multiple Packers:
 
Condition of approval:
Test Data:Wellbore Channel Test:
Reading TypePressure
10 MIN CASE1255
5 MIN CASE1255
FINAL CASE1255
FINAL TUBE1984
INITIAL TUBE1984
LOSS OR GAIN-5
START CASE1260
No channel test.