Skip to Main Content

Incident Search

COGIS - Mechanical Integrity Test Report
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-103-07191CARNEY UNIT
2X
SCOUT ENERGY MANAGEMENT LLC
10779
IJ
12/1/2019
RANGELY
72370
RIO BLANCO  103
NENE 4 1N102W 6
314772View Related Related
 
Form 21View Related Related View DocsDoc
Date Submitted:1/21/2019MIT Assigned By:
Date Recv'd:1/21/2019Facility ID: 
DocNum:401911403Facility Status:
Operator Information:
Oper. No.16700
Operator:CHEVRON USA INC
Address:100 CHEVRON RD  RANGELY  CO 81648
Type Of Facility:Well Status: 
Facility NameCARNEY UNIT
Operator contact:DIANE  PETERSON
Location:  qtrqtr:  section:  township:  range:  meridian: 
MIT Details:
Test Type:VERIFICATION OF REPAIRS
Repair Type:
Repair Desc:WELLWORK TO FISH PACKERS, CLEAN OUT WELLBORE AND RUN FIBERLINED TUBING AND PACKER. NO DOWNHOLE CHANGES.
Test Date:1/17/2019
Field Rep:Browning, Chuck
Approved Date:1/23/2019
Approved by:
Last Approved MIT:3/14/2018
Injection/Producing Formation Zones:WEBR
Perforation Interval:5625-6382
Open Hole Interval:
Bridge/Cement Plug Depth:
Tubing Size:2.875
Tubing Depth:5594.5
Top Packer Depth:5507.5
Multiple Packers:
 
Condition of approval:
Test Data:Wellbore Channel Test:
Reading TypePressure
10 MIN CASE1330
5 MIN CASE1340
FINAL CASE1330
LOSS OR GAIN-20
START CASE1350
No channel test.