Skip to Main Content

Incident Search

COGIS - Mechanical Integrity Test Report
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-123-20517WACKER
32-10
PDC ENERGY INC
69175
PA
2/18/2020
WATTENBERG
90750
WELD  123
SWNE 10 5N64W 6
331337View Related Related
 
Form 21View Related Related View DocsDoc
Date Submitted:11/2/2015MIT Assigned By:
Date Recv'd:11/2/2015Facility ID: 
DocNum:400928634Facility Status:
Operator Information:
Oper. No.69175
Operator:PDC ENERGY INC
Address:1775 SHERMAN STREET - STE 3000  DENVER  CO 80203
Type Of Facility:Well Status: 
Facility NameWACKER
Operator contact:Jenifer  Hakkarinen
Location:  qtrqtr:  section:  township:  range:  meridian: 
MIT Details:
Test Type:SI/TA MAINTENANCE STATUS
Test Date:10/26/2015
Field Rep:
Approved Date:11/2/2015
Approved by:
Last Approved MIT:N/A
Injection/Producing Formation Zones:CODL
Perforation Interval:6774-6784
Open Hole Interval:
Bridge/Cement Plug Depth:6725
Tubing Size:
Tubing Depth:
Top Packer Depth:
Multiple Packers:
 
Condition of approval:
Test Data:Wellbore Channel Test:
Reading TypePressure
10 MIN CASE534
5 MIN CASE534
FINAL CASE534
LOSS OR GAIN-4
START CASE537
No channel test.