Skip to Main Content

Incident Search

COGIS - Mechanical Integrity Test Report
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-103-07574UNION PACIFIC
92X-28
SCOUT ENERGY MANAGEMENT LLC
10779
AC
5/1/2023
RANGELY
72370
RIO BLANCO  103
NESW 28 2N102W 6
314934View Related Related
 
Form 21View Related Related View DocsDoc
Date Submitted:1/25/1999MIT Assigned By:ADKINS, JAIME
Date Recv'd:4/30/2003Facility ID: 150200
DocNum:240421Facility Status:AC
Operator Information:
Oper. No.16700
Operator:CHEVRON U S A INC
Address:P O BOX 4791  HOUSTON  TX 77210-4791
Type Of Facility:UIC ENHANCED RECOVERYWell Status: AC
Facility NameUNION PACIFIC
Operator contact: 
Location:  qtrqtr: SENE section: 16 township: 2N range: 103W meridian: 6
MIT Details:
Test Type:SI/TA MAINTENANCE STATUS
Test Date:1/18/1999
Field Rep:
Approved Date:3/18/1999
Approved by:ADKINS, JAIME
Last Approved MIT:8/7/1997
Injection/Producing Formation Zones:WEBR
Perforation Interval:5640-6433
Open Hole Interval:NA
Bridge/Cement Plug Depth:NA
Tubing Size:2.875
Tubing Depth:6363
Top Packer Depth:5167
Multiple Packers:Y
 
Condition of approval:
Test Data:Wellbore Channel Test:
Reading TypePressure
10 MIN CASE800
5 MIN CASE800
CASE BEFORE
FINAL CASE795
FINAL TUBE0
INITIAL TUBE0
LOSS OR GAIN-5
START CASE800
No channel test.