Skip to Main Content

Incident Search

COGIS - Mechanical Integrity Test Report
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-103-05812MCLAUGHLIN, A C
32
SCOUT ENERGY MANAGEMENT LLC
10779
IJ
11/17/2021
RANGELY
72370
RIO BLANCO  103
SWNE 13 2N103W 6
314486View Related Related
 
Form 21View Related Related View DocsDoc
Date Submitted:10/29/2014MIT Assigned By:Granahan, Kyle
Date Recv'd:10/30/2014Facility ID: 150200
DocNum:2125032Facility Status:AC
Operator Information:
Oper. No.16700
Operator:CHEVRON PRODUCTION COMPANY
Address:100 CHEVRON RD  RANGELY  CO 81648
Type Of Facility:UIC ENHANCED RECOVERYWell Status: AC
Facility NameMCLAUGHLIN, A C
Operator contact:DIANE  PETERSON
Location:  qtrqtr: SENE section: 16 township: 2N range: 103W meridian: 6
MIT Details:
Test Type:VERIFICATION OF REPAIRS
Repair Type:TUBING/PACKER LEAK
Repair Desc:Replace 187 joints 2 7/8" fiberlined tubing and packers.
Test Date:10/29/2014
Field Rep:Granahan, Kyle
Approved Date:10/30/2014
Approved by:Granahan, Kyle
Last Approved MIT:5/7/2013
Injection/Producing Formation Zones:WEBR
Perforation Interval:NA
Open Hole Interval:6350-6690
Bridge/Cement Plug Depth:NA
Tubing Size:2.875"
Tubing Depth:6152.4
Top Packer Depth:6032.7
Multiple Packers:Y
 
Condition of approval:
Test Data:Wellbore Channel Test:
Reading TypePressure
10 MIN CASE1200
5 MIN CASE1205
CASE BEFORE0
FINAL CASE1200
FINAL TUBE0
INITIAL TUBE0
LOSS OR GAIN-10
START CASE1210
No channel test.