Form 21 | Related Doc | Date Submitted: | 2/14/2014 | MIT Assigned By: | Covington, Dave | Date Recv'd: | 2/18/2014 | Facility ID: | 150200 | DocNum: | 2125010 | Facility Status: | AC | Operator Information: | Oper. No. | 16700 | Operator: | CHEVRON PRODUCTION COMPANY | Address: | 100 CHEVRON RD RANGELY CO 81648 | Type Of Facility: | UIC ENHANCED RECOVERY | Well Status: AC | Facility Name | UNION PACIFIC | Operator contact: | DIANE PETERSON | Location: | | qtrqtr: SENE | section: 16 | township: 2N | range: 103W | meridian: 6 |
| MIT Details: | Test Type: | VERIFICATION OF REPAIRS | Repair Type: | CASING LEAK | Repair Desc: | Run Liner | Test Date: | 2/14/2014 | Field Rep: | Covington, Dave | Approved Date: | 2/18/2014 | Approved by: | Covington, Dave | Last Approved MIT: | 3/3/2009 | Injection/Producing Formation Zones: | WEBR | Perforation Interval: | 5796-6264 | Open Hole Interval: | NA | Bridge/Cement Plug Depth: | | Tubing Size: | 2.875 | Tubing Depth: | 5738 | Top Packer Depth: | 5619 | Multiple Packers: | Y | | Condition of approval: | | Test Data: | Wellbore Channel Test: | Reading Type | Pressure | 10 MIN CASE | 1200 | 5 MIN CASE | 1200 | CASE BEFORE | 0 | FINAL CASE | 1200 | FINAL TUBE | 0 | INITIAL TUBE | 0 | LOSS OR GAIN | 0 | START CASE | 1200 |
| No channel test. |
|
|
|
|
|