Skip to Main Content

Incident Search

COGIS - Mechanical Integrity Test Report
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-103-08027FEE
111X
SCOUT ENERGY MANAGEMENT LLC
10779
AC
6/1/2023
RANGELY
72370
RIO BLANCO  103
NESW 19 2N102W 6
315173View Related Related
 
Form 21View Related Related View DocsDoc
Date Submitted:N/AMIT Assigned By:Covington, Dave
Date Recv'd:11/22/2013Facility ID: 150200
DocNum:2125002Facility Status:AC
Operator Information:
Oper. No.16700
Operator:CHEVRON PRODUCTION COMPANY
Address:100 CHEVRON RD  RANGELY  CO 81648
Type Of Facility:UIC ENHANCED RECOVERYWell Status: AC
Facility NameFEE
Operator contact:DIANE  PETERSON
Location:  qtrqtr: SENE section: 16 township: 2N range: 103W meridian: 6
MIT Details:
Test Type:VERIFICATION OF REPAIRS
Repair Type:TUBING/PACKER LEAK
Repair Desc:Cleaned out Wellbore, pumped 15% HCL, log well, fish packers, run 5 1/2" liner.
Test Date:11/21/2013
Field Rep:Covington, Dave
Approved Date:11/22/2013
Approved by:Covington, Dave
Last Approved MIT:4/12/2010
Injection/Producing Formation Zones:WEBR
Perforation Interval:5902-6455
Open Hole Interval:NA
Bridge/Cement Plug Depth:
Tubing Size:2.875
Tubing Depth:6485
Top Packer Depth:4944
Multiple Packers:Y
 
Condition of approval:
Test Data:Wellbore Channel Test:
Reading TypePressure
10 MIN CASE1200
5 MIN CASE1200
CASE BEFORE0
FINAL CASE1200
FINAL TUBE0
INITIAL TUBE0
LOSS OR GAIN0
START CASE1200
No channel test.