Skip to Main Content

Incident Search

COGIS - Field Inspection Report
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-103-06136GRAY
A-16
SCOUT ENERGY MANAGEMENT LLC
10779
IJ
4/29/2019
RANGELY
72370
RIO BLANCO  103
NWNW 19 2N102W 6
314566View Related Related
 
View Related RelatedView GISGISView Docs Doc
API Number: 05-103-06136Name: GRAY #A-16
Location: NWNW 19 2N102WLat: 40.133994   Long: -108.892961
Operator #: 16700Operator Name: CHEVRON U S A INC
Inspection Date: 5/12/2005Inspector: Jay Krabacher
Inspection was: Unsatisfactory
Insp. Type: RTInsp. Stat: SIReclamation (Pass, Interim Or Fail): FP&A (Pass/Fail): 
Brhd. Pressure: Inj. Pressure: T-C Ann. Pressure: 100UIC Violation Type: MI
Violation: YNOAV Sent: YDate Corrective Action Due: N/ADate Remedied: N/A
 
Field Inspection Comments And Observations
Insp. CommentInspection/Violation Comments
ACTION FIX ! OR P&A. EITHER WAY, NOTIFY COGCC WHEN REPAIRED AND MIT TO BE DONE -- OR WHEN P & A TO BE DONE.
UICCOM STILL ~ 100 PSI AFTER 2 MIN BLEED OFF. FAIL



 


Tuesday, November 12, 2024