Skip to Main Content

Incident Search

COGIS - Field Inspection Report
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-123-10637SOONER UNIT
10-28
FOUNDATION ENERGY MANAGEMENT LLC
10112
PA
3/21/2019
SOONER
77700
WELD  123
NWSE 28 8N58W 6
319078View Related Related
 
View Related RelatedView GISGISView Docs Doc
API Number: 05-123-10637Name: SOONER UNIT #10-28
Location: NWSE 28 8N58WLat: 40.630930   Long: -103.865690
Operator #: 24461Operator Name: DIVERSIFIED OPERATING CORPORATION
Inspection Date: 8/1/2002Inspector: Ed Binkley
Inspection was: Satisfactory
Insp. Type: RTInsp. Stat: ACReclamation (Pass, Interim Or Fail): PP&A (Pass/Fail): 
Brhd. Pressure: 0Inj. Pressure: 920T-C Ann. Pressure: 0UIC Violation Type: 
Violation: NNOAV Sent: NDate Corrective Action Due: 8/2/2002Date Remedied: N/A
 
Field Inspection Comments And Observations
Insp. CommentInspection/Violation Comments
ACTION REMOVE CHECK VALVE ON CASING SIDE.
UICCOM CHECK VALVE LEAKING PRESSURE TO CASING SIDE. DISCONNECT FLOWLINE TO CHECK ON CSG SIDE.
WELLSIGN POOR CONDITION



 