Skip to Main Content

Incident Search

COGIS - Mechanical Integrity Test Report
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-103-09173UNION PACIFIC
138Y-28
SCOUT ENERGY MANAGEMENT LLC
10779
PR
4/1/2019
RANGELY
72370
RIO BLANCO  103
NWSW 28 2N102W 6
315751View Related Related
 
Form 21View Related Related View DocsDoc
Date Submitted:4/5/2012MIT Assigned By:KOEHLER, BOB
Date Recv'd:4/9/2012API number: 05-103-09173
DocNum:1771790Facility Status:PR
Operator Information:
Oper. No.16700
Operator:CHEVRON USA INC
Address:6001 BOLLINGER CANYON RD  SAN RAMON  CA 94583
Type Of Facility:WELLWell Status: PR
Well Name/No.UNION PACIFIC
Operator contact:DIANE L.  PETERSON
Location:  qtrqtr: NWSW section: 28 township: 2N range: 102W meridian: 6
MIT Details:
Test Type:SI/TA MAINTENANCE STATUS
Test Date:3/4/2012
Field Rep:
Approved Date:4/9/2012
Approved by:KOEHLER, BOB
Last Approved MIT:N/A
Injection/Producing Formation Zones:WEBR
Perforation Interval:5617-6243
Open Hole Interval:NA
Bridge/Cement Plug Depth:NA
Tubing Size:2.875
Tubing Depth:5590
Top Packer Depth:5522
Multiple Packers:N
 
Condition of approval:
Acceptable pressure drop, within 10% range. Chart shows rapid initial drop 600 psi to 550 psi and then relatively long period of stability.
Test Data:Wellbore Channel Test:
Reading TypePressure
10 MIN CASE
5 MIN CASE
CASE BEFORE
FINAL CASE550
FINAL TUBE
INITIAL TUBE
LOSS OR GAIN-50
START CASE600
No channel test.