WELL05-103-05699MCLAUGHLIN
28
SCOUT ENERGY MANAGEMENT LLC
10779
PR
12/1/2021
RANGELY
72370
RIO BLANCO  103
SWSW 23 2N103W 6
314440View Related Related
 
Form 21View Related Related View DocsDoc
Date Submitted:3/16/2012MIT Assigned By:KOEHLER, BOB
Date Recv'd:3/21/2012API number: 05-103-05699
DocNum:1771732Facility Status:PR
Operator Information:
Oper. No.16700
Operator:CHEVRON USA INC
Address:100 CHEVRON ROAD  RANGELY  CO 81648
Type Of Facility:WELLWell Status: PR
Well Name/No.MCLAUGHLIN
Operator contact:DIANE L.  PETERSON
Location:  qtrqtr: SWSW section: 23 township: 2N range: 103W meridian: 6
MIT Details:
Test Type:SI/TA MAINTENANCE STATUS
Test Date:3/15/2012
Field Rep:
Approved Date:3/22/2012
Approved by:KOEHLER, BOB
Last Approved MIT:N/A
Injection/Producing Formation Zones:WEBR
Perforation Interval:NA
Open Hole Interval:6210-6715
Bridge/Cement Plug Depth:NA
Tubing Size:2.875
Tubing Depth:6129
Top Packer Depth:6124
Multiple Packers:N
 
Condition of approval:
BK-Requested Forms 5 and 5A to fill in gaps. Diane entered both via eForm on 3/29/2012. Sand plug at 6590 placed in 2001 has been removed.
Test Data:Wellbore Channel Test:
Reading TypePressure
10 MIN CASE
5 MIN CASE
CASE BEFORE0
FINAL CASE375
FINAL TUBE0
INITIAL TUBE
LOSS OR GAIN0
START CASE375
No channel test.