Skip to Main Content

Incident Search

COGIS - Mechanical Integrity Test Report
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-103-09149C.T. CARNEY
41-Y34
SCOUT ENERGY MANAGEMENT LLC
10779
AC
6/1/2023
RANGELY
72370
RIO BLANCO  103
NENW 34 2N102W 6
315740View Related Related
 
Form 21View Related Related View DocsDoc
Date Submitted:2/14/2012MIT Assigned By:KOEHLER, BOB
Date Recv'd:2/16/2012API number: 05-103-09149
DocNum:1771702Facility Status:AC
Operator Information:
Oper. No.16700
Operator:CHEVRON USA INC
Address:100 CHEVRON ROAD  RANGELY  CO 81648
Type Of Facility:WELLWell Status: AC
Well Name/No.C.T. CARNEY
Operator contact:DIANE L.  PETERSON
Location:  qtrqtr: NENW section: 34 township: 2N range: 102W meridian: 6
MIT Details:
Test Type:SI/TA MAINTENANCE STATUS
Test Date:2/13/2012
Field Rep:
Approved Date:2/21/2012
Approved by:KOEHLER, BOB
Last Approved MIT:4/3/2007
Injection/Producing Formation Zones:WEBR
Perforation Interval:5669-6323
Open Hole Interval:NA
Bridge/Cement Plug Depth:5969
Tubing Size:2.875
Tubing Depth:5677
Top Packer Depth:5609
Multiple Packers:N
 
Condition of approval:
Test Data:Wellbore Channel Test:
Reading TypePressure
10 MIN CASE
5 MIN CASE
CASE BEFORE
FINAL CASE500
FINAL TUBE
INITIAL TUBE
LOSS OR GAIN0
START CASE500
No channel test.