Form 21 | Related Doc | Date Submitted: | 6/3/2010 | MIT Assigned By: | KOEHLER, BOB | Date Recv'd: | 6/7/2010 | API number: | 05-103-06092 | DocNum: | 1770765 | Facility Status: | AC | Operator Information: | Oper. No. | 16700 | Operator: | CHEVRON U S A INC | Address: | 6001 BOLLINGER CANYON RD SAN RAMON CA 94583 | Type Of Facility: | WELL | Well Status: AC | Well Name/No. | A C MCLAUGHLIN A | Operator contact: | DIANE L PETERSON | Location: | | qtrqtr: NENE | section: 5 | township: 1N | range: 102W | meridian: 6 |
| MIT Details: | Test Type: | RESET PACKER | Test Date: | 5/3/2010 | Field Rep: | | Approved Date: | 6/8/2010 | Approved by: | KOEHLER, BOB | Last Approved MIT: | 6/2/2008 | Injection/Producing Formation Zones: | WEBR | Perforation Interval: | NA | Open Hole Interval: | 5727-6277 | Bridge/Cement Plug Depth: | NA | Tubing Size: | 2.875 | Tubing Depth: | 5659 | Top Packer Depth: | 5622 | Multiple Packers: | N | | Condition of approval: | | Test Data: | Wellbore Channel Test: | Reading Type | Pressure | 10 MIN CASE | | 5 MIN CASE | | CASE BEFORE | 0 | FINAL CASE | 790 | FINAL TUBE | | INITIAL TUBE | | LOSS OR GAIN | -10 | START CASE | 800 |
| No channel test. |
|
|
|
|
|