Skip to Main Content

Incident Search

COGIS - Mechanical Integrity Test Report
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-103-10708A.C. MCLAUGHLIN
92X
SCOUT ENERGY MANAGEMENT LLC
10779
PR
2/1/2011
RANGELY
72370
RIO BLANCO  103
NENE 15 2N103W 6
316521View Related Related
 
Form 21View Related Related View DocsDoc
Date Submitted:6/3/2010MIT Assigned By:KOEHLER, BOB
Date Recv'd:6/7/2010API number: 05-103-10708
DocNum:1770762Facility Status:PR
Operator Information:
Oper. No.16700
Operator:CHEVRON U S A INC
Address:6001 BOLLINGER CANYON RD  SAN RAMON  CA 94583
Type Of Facility:WELLWell Status: PR
Well Name/No.A.C. MCLAUGHLIN
Operator contact:DIANE L  PETERSON
Location:  qtrqtr: NENE section: 15 township: 2N range: 103W meridian: 6
MIT Details:
Test Type:SI/TA MAINTENANCE STATUS
Test Date:5/18/2010
Field Rep:
Approved Date:6/8/2010
Approved by:KOEHLER, BOB
Last Approved MIT:N/A
Injection/Producing Formation Zones:WEBR
Perforation Interval:NA
Open Hole Interval:6544-6750
Bridge/Cement Plug Depth:NA
Tubing Size:2.875
Tubing Depth:6418
Top Packer Depth:6381
Multiple Packers:N
 
Condition of approval:
Test Data:Wellbore Channel Test:
Reading TypePressure
10 MIN CASE
5 MIN CASE
CASE BEFORE0
FINAL CASE850
FINAL TUBE
INITIAL TUBE
LOSS OR GAIN0
START CASE850
No channel test.