Skip to Main Content

Incident Search

COGIS - Mechanical Integrity Test Report
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-103-06131GRAY B
6
SCOUT ENERGY MANAGEMENT LLC
10779
IJ
5/31/2023
RANGELY
72370
RIO BLANCO  103
NWNE 18 2N102W 6
397173View Related Related
 
Form 21View Related Related View DocsDoc
Date Submitted:4/29/2008MIT Assigned By:KOEHLER, BOB
Date Recv'd:5/1/2008API number: 05-103-06131
DocNum:1618893Facility Status:IJ
Operator Information:
Oper. No.16700
Operator:CHEVRON U S A INC
Address:100 CHEVRON ROAD  RANGELY  CO 81648
Type Of Facility:WELLWell Status: IJ
Well Name/No.GRAY B
Operator contact:DIANE L  PETERSON
Location:  qtrqtr: NWNE section: 18 township: 2N range: 102W meridian: 6
MIT Details:
Test Type:VERIFICATION OF REPAIRS
Repair Type:OTHER
Repair Desc:RE-ENTER P&A WELL, CLEAN OUT TO OWC AND RUN 200 JOINTS 2 7/8" DYB FIBERLINED TUBING.
Test Date:4/21/2008
Field Rep:
Approved Date:10/1/2008
Approved by:KOEHLER, BOB
Last Approved MIT:11/30/1989
Injection/Producing Formation Zones:WEBR
Perforation Interval:NA
Open Hole Interval:6425-6520
Bridge/Cement Plug Depth:
Tubing Size:2.875
Tubing Depth:6423
Top Packer Depth:6335
Multiple Packers:Y
 
Condition of approval:
Test Data:Wellbore Channel Test:
Reading TypePressure
No test data.
No channel test.