Skip to Main Content

Incident Search

COGIS - Mechanical Integrity Test Report
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-103-07351LEVISON
30X
SCOUT ENERGY MANAGEMENT LLC
10779
IJ
4/21/2023
RANGELY
72370
RIO BLANCO  103
SENE 27 2N102W 6
314834View Related Related
 
Form 21View Related Related View DocsDoc
Date Submitted:11/25/2002MIT Assigned By:ADKINS, JAIME
Date Recv'd:4/25/2003Facility ID: 150200
DocNum:1253752Facility Status:AC
Operator Information:
Oper. No.16700
Operator:CHEVRON U S A INC
Address:P O BOX 4791  HOUSTON  TX 77210-4791
Type Of Facility:UIC ENHANCED RECOVERYWell Status: AC
Facility NameLEVISON
Operator contact: 
Location:  qtrqtr: SENE section: 16 township: 2N range: 103W meridian: 6
MIT Details:
Test Type:VERIFICATION OF REPAIRS
Repair Type:TUBING/PACKER LEAK
Repair Desc:REPLACE TBG
Test Date:11/21/2002
Field Rep:
Approved Date:1/9/2003
Approved by:ADKINS, JAIME
Last Approved MIT:5/16/2001
Injection/Producing Formation Zones:WEBR
Perforation Interval:6004-6490
Open Hole Interval:NA
Bridge/Cement Plug Depth:NA
Tubing Size:2.875
Tubing Depth:5787
Top Packer Depth:5750
Multiple Packers:N
 
Condition of approval:
Test Data:Wellbore Channel Test:
Reading TypePressure
10 MIN CASE800
5 MIN CASE800
CASE BEFORE
FINAL CASE800
FINAL TUBE
INITIAL TUBE
LOSS OR GAIN0
START CASE800
No channel test.