Skip to Main Content

Incident Search

COGIS - Mechanical Integrity Test Report
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-103-06125GRAY
B-9
SCOUT ENERGY MANAGEMENT LLC
10779
IJ
1/1/1999
RANGELY
72370
RIO BLANCO  103
NWSW 18 2N102W 6
314560View Related Related
 
Form 21View Related Related View DocsDoc
Date Submitted:10/8/2003MIT Assigned By:ADKINS, JAIME
Date Recv'd:2/2/2004Facility ID: 150200
DocNum:1241671Facility Status:AC
Operator Information:
Oper. No.16700
Operator:CHEVRON U S A INC
Address:100 CHEVRON RD  RANGELY  CO 81648
Type Of Facility:UIC ENHANCED RECOVERYWell Status: AC
Facility NameGRAY
Operator contact:DIANNE  PETERSON
Location:  qtrqtr: SENE section: 16 township: 2N range: 103W meridian: 6
MIT Details:
Test Type:VERIFICATION OF REPAIRS
Repair Type:TUBING/PACKER AND CASING LEAK
Repair Desc:
Test Date:9/9/2003
Field Rep:
Approved Date:2/2/2002
Approved by:ADKINS, JAIME
Last Approved MIT:5/17/2001
Injection/Producing Formation Zones:WEBR
Perforation Interval:5290-5598
Open Hole Interval:NA
Bridge/Cement Plug Depth:
Tubing Size:2.875
Tubing Depth:6546
Top Packer Depth:5999
Multiple Packers:Y
 
Condition of approval:
Test Data:Wellbore Channel Test:
Reading TypePressure
10 MIN CASE800
5 MIN CASE800
CASE BEFORE0
FINAL CASE800
FINAL TUBE0
INITIAL TUBE0
LOSS OR GAIN0
START CASE800
Channel TestTest Date
TRACER SURVEY 10/6/2003