Skip to Main Content

Incident Search

COGIS - Mechanical Integrity Test Report
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-103-07216LARSON, F V
A-2X
SCOUT ENERGY MANAGEMENT LLC
10779
AC
6/1/2023
RANGELY
72370
RIO BLANCO  103
SWSE 34 2N102W 6
314780View Related Related
 
Form 21View Related Related View DocsDoc
Date Submitted:5/12/2003MIT Assigned By:KRABACHER, JAY
Date Recv'd:9/30/2003Facility ID: 150200
DocNum:1191044Facility Status:AC
Operator Information:
Oper. No.16700
Operator:CHEVRON U S A INC
Address:P O BOX 4791  HOUSTON  TX 77210
Type Of Facility:UIC ENHANCED RECOVERYWell Status: AC
Facility NameLARSON, F V
Operator contact:D  PETERSON
Location:  qtrqtr: SENE section: 16 township: 2N range: 103W meridian: 6
MIT Details:
Test Type:5-YEAR UIC TEST
Test Date:5/6/2003
Field Rep:KRABACHER, JAY
Approved Date:9/30/2003
Approved by:KRABACHER, JAY
Last Approved MIT:9/8/1998
Injection/Producing Formation Zones:WEBR
Perforation Interval:5594-6369
Open Hole Interval:NA
Bridge/Cement Plug Depth:
Tubing Size:2.875
Tubing Depth:6090
Top Packer Depth:5247
Multiple Packers:Y
 
Condition of approval:
Test Data:Wellbore Channel Test:
Reading TypePressure
10 MIN CASE825
5 MIN CASE825
CASE BEFORE0
FINAL CASE820
FINAL TUBE0
INITIAL TUBE0
LOSS OR GAIN-10
START CASE830
Channel TestTest Date
TRACER SURVEY 9/8/1997