Skip to Main Content

Incident Search

COGIS - Mechanical Integrity Test Report
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-103-06247FEE
44
SCOUT ENERGY MANAGEMENT LLC
10779
IJ
12/1/2019
RANGELY
72370
RIO BLANCO  103
SESE 30 2N102W 6
314630View Related Related
 
Form 21View Related Related View DocsDoc
Date Submitted:10/22/2014MIT Assigned By:Browning, Chuck
Date Recv'd:10/23/2014Facility ID: 150200
DocNum:1171738Facility Status:AC
Operator Information:
Oper. No.16700
Operator:CHEVRON PRODUCTION COMPANY
Address:100 CHEVRON RD  RANGELY  CO 81648
Type Of Facility:UIC ENHANCED RECOVERYWell Status: AC
Facility NameFEE
Operator contact:DIANE  PETERSON
Location:  qtrqtr: SENE section: 16 township: 2N range: 103W meridian: 6
MIT Details:
Test Type:5-YEAR UIC TEST
Test Date:10/22/2014
Field Rep:Browning, Chuck
Approved Date:10/22/2014
Approved by:Browning, Chuck
Last Approved MIT:6/12/2010
Injection/Producing Formation Zones:WEBR
Perforation Interval:5666-6224
Open Hole Interval:NA
Bridge/Cement Plug Depth:NA
Tubing Size:2.875
Tubing Depth:5409.5
Top Packer Depth:5335.4
Multiple Packers:Y
 
Condition of approval:
Test Data:Wellbore Channel Test:
Reading TypePressure
10 MIN CASE1160
5 MIN CASE1200
CASE BEFORE0
FINAL CASE1160
FINAL TUBE2120
INITIAL TUBE2120
LOSS OR GAIN-50
START CASE1210
No channel test.