Skip to Main Content

Incident Search

COGIS - Mechanical Integrity Test Report
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-103-06198LEVISON
11
SCOUT ENERGY MANAGEMENT LLC
10779
IJ
1/10/2022
RANGELY
72370
RIO BLANCO  103
NWSE 26 2N102W 6
314602View Related Related
 
Form 21View Related Related View DocsDoc
Date Submitted:9/12/2014MIT Assigned By:Browning, Chuck
Date Recv'd:9/16/2014Facility ID: 150200
DocNum:1171715Facility Status:AC
Operator Information:
Oper. No.16700
Operator:CHEVRON PRODUCTION COMPANY
Address:100 CHEVRON RD  RANGELY  CO 81648
Type Of Facility:UIC ENHANCED RECOVERYWell Status: AC
Facility NameLEVISON
Operator contact:DIANE  PETERSON
Location:  qtrqtr: SENE section: 16 township: 2N range: 103W meridian: 6
MIT Details:
Test Type:5-YEAR UIC TEST
Test Date:9/12/2014
Field Rep:Browning, Chuck
Approved Date:9/12/2014
Approved by:Browning, Chuck
Last Approved MIT:4/14/2010
Injection/Producing Formation Zones:WEBR
Perforation Interval:NA
Open Hole Interval:5978-6313
Bridge/Cement Plug Depth:NA
Tubing Size:2.875
Tubing Depth:6169.9
Top Packer Depth:5739.1
Multiple Packers:Y
 
Condition of approval:
Test Data:Wellbore Channel Test:
Reading TypePressure
10 MIN CASE1220
5 MIN CASE1225
CASE BEFORE0
FINAL CASE1220
FINAL TUBE1700
INITIAL TUBE1700
LOSS OR GAIN-5
START CASE1225
No channel test.