Skip to Main Content

Incident Search

COGIS - Mechanical Integrity Test Report
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-103-09239EMERALD
33AX
SCOUT ENERGY MANAGEMENT LLC
10779
IJ
7/16/2021
RANGELY
72370
RIO BLANCO  103
NWSW 30 2N102W 6
315790View Related Related
 
Form 21View Related Related View DocsDoc
Date Submitted:4/10/2014MIT Assigned By:BROWNING, CHUCK
Date Recv'd:4/11/2014Facility ID: 150200
DocNum:1171628Facility Status:AC
Operator Information:
Oper. No.16700
Operator:CHEVRON PRODUCTION COMPANY
Address:100 CHEVRON RD  RANGELY  CO 81648
Type Of Facility:UIC ENHANCED RECOVERYWell Status: AC
Facility NameEMERALD
Operator contact:DIANE  PETERSON
Location:  qtrqtr: SENE section: 16 township: 2N range: 103W meridian: 6
MIT Details:
Test Type:VERIFICATION OF REPAIRS
Repair Type:CASING LEAK
Repair Desc:CASING PATCH
Test Date:4/10/2014
Field Rep:BROWNING, CHUCK
Approved Date:4/10/2014
Approved by:BROWNING, CHUCK
Last Approved MIT:3/16/2012
Injection/Producing Formation Zones:WEBR
Perforation Interval:5875-6312
Open Hole Interval:NA
Bridge/Cement Plug Depth:
Tubing Size:2.875
Tubing Depth:5686.8
Top Packer Depth:5607.9
Multiple Packers:Y
 
Condition of approval:
Test Data:Wellbore Channel Test:
Reading TypePressure
10 MIN CASE1210
5 MIN CASE1210
CASE BEFORE0
FINAL CASE1210
FINAL TUBE0
INITIAL TUBE0
LOSS OR GAIN0
START CASE1210
No channel test.