COGIS - Mechanical Integrity Test Report
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-103-07689GRAY
A-17X
SCOUT ENERGY MANAGEMENT LLC
10779
IJ
8/15/2014
RANGELY
72370
RIO BLANCO  103
SESE 13 2N103W 6
314984View Related Related
 
Form 21View Related Related View DocsDoc
Date Submitted:3/25/2014MIT Assigned By:BROWNING, CHUCK
Date Recv'd:3/27/2014Facility ID: 150200
DocNum:1171583Facility Status:AC
Operator Information:
Oper. No.16700
Operator:CHEVRON PRODUCTION COMPANY
Address:100 CHEVRON RD  RANGELY  CO 81648
Type Of Facility:UIC ENHANCED RECOVERYWell Status: AC
Facility NameGRAY
Operator contact:DIANE  PETERSON
Location:  qtrqtr: SENE section: 16 township: 2N range: 103W meridian: 6
MIT Details:
Test Type:5-YEAR UIC TEST
Test Date:3/25/2014
Field Rep:BROWNING, CHUCK
Approved Date:3/25/2014
Approved by:BROWNING, CHUCK
Last Approved MIT:5/18/2009
Injection/Producing Formation Zones:WEBR
Perforation Interval:6246-6590
Open Hole Interval:NA
Bridge/Cement Plug Depth:
Tubing Size:2.875
Tubing Depth:6136.7
Top Packer Depth:6052.4
Multiple Packers:Y
 
Condition of approval:
Test Data:Wellbore Channel Test:
Reading TypePressure
10 MIN CASE1275
5 MIN CASE1275
CASE BEFORE0
FINAL CASE1275
FINAL TUBE1380
INITIAL TUBE1380
LOSS OR GAIN0
START CASE1275
No channel test.