Skip to Main Content

Incident Search

COGIS - Mechanical Integrity Test Report
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-103-05599EMERALD
3
SCOUT ENERGY MANAGEMENT LLC
10779
IJ
8/17/2015
RANGELY
72370
RIO BLANCO  103
SWSW 30 2N102W 6
314397View Related Related
 
Form 21View Related Related View DocsDoc
Date Submitted:10/22/2013MIT Assigned By:BROWNING, CHUCK
Date Recv'd:10/23/2013Facility ID: 150200
DocNum:1171561Facility Status:AC
Operator Information:
Oper. No.16700
Operator:CHEVRON PRODUCTION COMPANY
Address:100 CHEVRON RD  RANGELY  CO 81648
Type Of Facility:UIC ENHANCED RECOVERYWell Status: AC
Facility NameEMERALD
Operator contact:DIANE  PETERSON
Location:  qtrqtr: SENE section: 16 township: 2N range: 103W meridian: 6
MIT Details:
Test Type:VERIFICATION OF REPAIRS
Repair Type:OTHER
Repair Desc:WELLWORK TO PLUGBACK WEBER FORMATION. SIDETRACK AND RUN LINER FROM SURFACE TO NEW TD IN WEBER FORMATION
Test Date:10/22/2013
Field Rep:BROWNING, CHUCK
Approved Date:10/22/2013
Approved by:BROWNING, CHUCK
Last Approved MIT:N/A
Injection/Producing Formation Zones:WEBR
Perforation Interval:5826-6413
Open Hole Interval:NA
Bridge/Cement Plug Depth:
Tubing Size:2.875
Tubing Depth:5818
Top Packer Depth:5740
Multiple Packers:Y
 
Condition of approval:
Test Data:Wellbore Channel Test:
Reading TypePressure
10 MIN CASE1250
5 MIN CASE1250
CASE BEFORE0
FINAL CASE1250
FINAL TUBE0
INITIAL TUBE0
LOSS OR GAIN0
START CASE1250
No channel test.