Skip to Main Content

Incident Search

COGIS - Mechanical Integrity Test Report
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-103-05595EMERALD
34
SCOUT ENERGY MANAGEMENT LLC
10779
IJ
4/21/2023
RANGELY
72370
RIO BLANCO  103
SESE 25 2N103W 6
314395View Related Related
 
Form 21View Related Related View DocsDoc
Date Submitted:10/8/2013MIT Assigned By:BROWNING, CHUCK
Date Recv'd:10/9/2013Facility ID: 150200
DocNum:1171558Facility Status:AC
Operator Information:
Oper. No.16700
Operator:CHEVRON PRODUCTION COMPANY
Address:100 CHEVRON RD  RANGELY  CO 81648
Type Of Facility:UIC ENHANCED RECOVERYWell Status: AC
Facility NameEMERALD
Operator contact:DIANE  PETERSON
Location:  qtrqtr: SENE section: 16 township: 2N range: 103W meridian: 6
MIT Details:
Test Type:VERIFICATION OF REPAIRS
Repair Type:TUBING/PACKER LEAK
Repair Desc:RUN NEW TUBING & PACKER
Test Date:10/8/2013
Field Rep:BROWNING, CHUCK
Approved Date:10/8/2013
Approved by:BROWNING, CHUCK
Last Approved MIT:6/6/2011
Injection/Producing Formation Zones:WEBR
Perforation Interval:5614-6361
Open Hole Interval:NA
Bridge/Cement Plug Depth:
Tubing Size:2.875
Tubing Depth:5476
Top Packer Depth:5478.5
Multiple Packers:Y
 
Condition of approval:
Test Data:Wellbore Channel Test:
Reading TypePressure
10 MIN CASE1180
5 MIN CASE1190
CASE BEFORE0
FINAL CASE1180
FINAL TUBE0
INITIAL TUBE0
LOSS OR GAIN-20
START CASE1200
No channel test.