Skip to Main Content

Incident Search

COGIS - Mechanical Integrity Test Report
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-103-05812MCLAUGHLIN, A C
32
SCOUT ENERGY MANAGEMENT LLC
10779
IJ
11/17/2021
RANGELY
72370
RIO BLANCO  103
SWNE 13 2N103W 6
314486View Related Related
 
Form 21View Related Related View DocsDoc
Date Submitted:5/15/2007MIT Assigned By:KRABACHER, JAY
Date Recv'd:6/18/2007Facility ID: 150200
DocNum:1170980Facility Status:AC
Operator Information:
Oper. No.16700
Operator:CHEVRON PRODUCTION COMPANY
Address:100 CHEVRON RD  RANGELY  CO 81648
Type Of Facility:UIC ENHANCED RECOVERYWell Status: AC
Facility NameMCLAUGHLIN, A C
Operator contact:DIANE  PETERSON
Location:  qtrqtr: SENE section: 16 township: 2N range: 103W meridian: 6
MIT Details:
Test Type:VERIFICATION OF REPAIRS
Repair Type:OTHER
Repair Desc:plugged back well from 6480 - 6690. perf'd and acidized O.H. 6350 - 6480.
Test Date:5/11/2007
Field Rep:
Approved Date:6/18/2007
Approved by:KRABACHER, JAY
Last Approved MIT:5/24/2005
Injection/Producing Formation Zones:WEBR
Perforation Interval:NA
Open Hole Interval:6350 - 6480
Bridge/Cement Plug Depth:
Tubing Size:2.875
Tubing Depth:6247
Top Packer Depth:6161
Multiple Packers:Y
 
Condition of approval:
Test Data:Wellbore Channel Test:
Reading TypePressure
10 MIN CASE800
5 MIN CASE805
CASE BEFORE0
FINAL CASE800
FINAL TUBE0
INITIAL TUBE0
LOSS OR GAIN-5
START CASE805
No channel test.