Skip to Main Content

Incident Search

COGIS - Mechanical Integrity Test Report
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-103-01051MCLAUGHLIN, A C
30
SCOUT ENERGY MANAGEMENT LLC
10779
IJ
11/1/2022
RANGELY
72370
RIO BLANCO  103
NENW 14 2N103W 6
314257View Related Related
 
Form 21View Related Related View DocsDoc
Date Submitted:5/10/2006MIT Assigned By:KRABACHER, JAY
Date Recv'd:7/21/2006Facility ID: 150200
DocNum:1170863Facility Status:AC
Operator Information:
Oper. No.16700
Operator:CHEVRON PRODUCTION COMPANY
Address:100 CHEVRON RD  RANGELY  CO 81648
Type Of Facility:UIC ENHANCED RECOVERYWell Status: AC
Facility NameMCLAUGHLIN, A C
Operator contact:DIANE  PETERSON
Location:  qtrqtr: SENE section: 16 township: 2N range: 103W meridian: 6
MIT Details:
Test Type:5-YEAR UIC TEST
Test Date:5/8/2006
Field Rep:KRABACHER, JAY
Approved Date:7/21/2006
Approved by:KRABACHER, JAY
Last Approved MIT:4/23/2001
Injection/Producing Formation Zones:WEBR
Perforation Interval:NA
Open Hole Interval:6501 - 6839
Bridge/Cement Plug Depth:
Tubing Size:2.875
Tubing Depth:6730
Top Packer Depth:6317
Multiple Packers:Y
 
Condition of approval:
Test Data:Wellbore Channel Test:
Reading TypePressure
10 MIN CASE815
5 MIN CASE825
CASE BEFORE0
FINAL CASE810
FINAL TUBE0
INITIAL TUBE0
LOSS OR GAIN-20
START CASE830
No channel test.