Skip to Main Content

Incident Search

COGIS - Mechanical Integrity Test Report
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-103-06075HEFLEY, M E
1
SCOUT ENERGY MANAGEMENT LLC
10779
PA
10/20/2014
RANGELY
72370
RANGELY/RIO BLANCO  103
NWNW 2 1N102W 6
314545View Related Related
 
Form 21View Related Related View DocsDoc
Date Submitted:6/29/2005MIT Assigned By:KRABACHER, JAY
Date Recv'd:7/21/2005API number: 05-103-06075
DocNum:1170766Facility Status:PA
Operator Information:
Oper. No.16700
Operator:CHEVRON PRODUCTION COMPANY
Address:100 CHEVRON RD  RANGELY  CO 81648
Type Of Facility:WELLWell Status: PA
Well Name/No.HEFLEY, M E
Operator contact:DIANE  PETERSON
Location:  qtrqtr: NWNW section: 2 township: 1N range: 102W meridian: 6
MIT Details:
Test Type:VERIFICATION OF REPAIRS
Repair Type:TUBING/PACKER LEAK
Repair Desc:replaced packer and 170 jts. tubing
Test Date:6/27/2005
Field Rep:
Approved Date:7/21/2005
Approved by:KRABACHER, JAY
Last Approved MIT:5/21/2001
Injection/Producing Formation Zones:WEBR
Perforation Interval:5679 - 6302
Open Hole Interval:NA
Bridge/Cement Plug Depth:
Tubing Size:2.875
Tubing Depth:5416
Top Packer Depth:5378
Multiple Packers:N
 
Condition of approval:
Test Data:Wellbore Channel Test:
Reading TypePressure
10 MIN CASE800
5 MIN CASE800
CASE BEFORE0
FINAL CASE800
FINAL TUBE0
INITIAL TUBE0
LOSS OR GAIN0
START CASE800
No channel test.