Skip to Main Content

Incident Search

COGIS - Mechanical Integrity Test Report
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-103-08026FEE
110X
SCOUT ENERGY MANAGEMENT LLC
10779
IJ
1/1/1999
RANGELY
72370
RIO BLANCO  103
NESW 19 2N102W 6
315172View Related Related
 
Form 21View Related Related View DocsDoc
Date Submitted:5/9/2005MIT Assigned By:KRABACHER, JAY
Date Recv'd:5/31/2005Facility ID: 150200
DocNum:1170701Facility Status:AC
Operator Information:
Oper. No.16700
Operator:CHEVRON PRODUCTION COMPANY
Address:100 CHEVRON RD  RANGELY  CO 81648
Type Of Facility:UIC ENHANCED RECOVERYWell Status: AC
Facility NameFEE
Operator contact:DIANE  PETERSON
Location:  qtrqtr: SENE section: 16 township: 2N range: 103W meridian: 6
MIT Details:
Test Type:5-YEAR UIC TEST
Test Date:5/3/2005
Field Rep:KRABACHER, JAY
Approved Date:5/12/2005
Approved by:KRABACHER, JAY
Last Approved MIT:6/15/2000
Injection/Producing Formation Zones:WEBR
Perforation Interval:5823 - 6498
Open Hole Interval:NA
Bridge/Cement Plug Depth:
Tubing Size:2.875
Tubing Depth:5778
Top Packer Depth:5559
Multiple Packers:N
 
Condition of approval:
Test Data:Wellbore Channel Test:
Reading TypePressure
10 MIN CASE815
5 MIN CASE815
CASE BEFORE0
FINAL CASE810
FINAL TUBE0
INITIAL TUBE0
LOSS OR GAIN-10
START CASE820
No channel test.