Click for Specifics | Light | 3/29/2025 | 4/14/2025 | | 1 | | -- | 0 | | 576 | 574 | No | No | No | |
403646090 | Form 17 | 1/3/2024 | 1/5/2024 | FLOWING | 2 | DOWN TO 0 | GAS | 0 | NO FLOW | 2076 | 2075 | No | -- | -- | Mitigation Bradenhead Test
WBD submitted on doc# 403617892. |
403604417 | Form 17 | 11/17/2023 | 11/22/2023 | SHUT-IN | 863 | SURGE | MUD AND GAS | 0 | WHISPER | 2597 | 2560 | No | -- | -- | Mitigation Bradenhead Test
WBD will be submitted on Form 5A.
Bradenhead was blown down to the facility to control erratic flow, causing restriction, so time to reach 0 psi is likely overstated. Gas present with surging muddy liquid. |
403604465 | Form 17 | 11/13/2023 | 11/22/2023 | FLOWING | 31 | DOWN TO 0 | GAS | 0 | NO FLOW | 2448 | 2505 | No | -- | -- | Post-Production Bradenhead Test
WBD will be submitted on Form 5A.
Bradenhead periodically surged liquid with the appearance of mud. There was not sufficient flow to draw the requisite sample volume of liquid so only a gas sample was taken. Facility equipment was used to control blowdown due to irregular multi-phase flow resulting in restrictions and overstated time to reach 0 psi. |
403468653 | Form 17 | 7/13/2023 | 7/18/2023 | SHUT-IN | 0 | NO FLOW | NONE | 0 | NO FLOW | 0 | 0 | No | -- | -- | Post-Rig Release Bradenhead Test
WBD will be submitted on Form 5A. Sample could not be collected |