Click for Specifics | Full | 7/17/2024 | 7/29/2024 | | 4 | Down to Zero | -- | 0 | No Flow | 581 | 589 | No | No | No | Annual Test. 4 PSI, with no pressure or flow observed for the entire 30-minute test. PDC will monitor pressure and re-test according to bradenhead policy. |
Click for Specifics | Full | 5/4/2023 | 5/15/2023 | | 3 | Down to Zero | -- | 0 | Down to Zero | 683 | 677 | No | None | None | Annual Test. 3 PSI blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. PDC will monitor pressure and re-test according to bradenhead policy. |
403264432 | Form 17 | 12/16/2022 | 12/19/2022 | FLOWING | 98 | DOWN TO 0 | GAS AND LIQUID HYDROCARBON | 0 | NO FLOW | 739 | 737 | Yes | -- | -- | Automation Alert follow-up. 98 PSI gas and fluid blew down to 0 PSI within first minute of test. 2 gallons of fluid the first 40 seconds, then steady trickle for next 2 minutes, then slow drip until 4 minute mark. Fluid began again at 13 minute mark and ended at 27 minute mark. ~2.5 gallon dark fluid. PDC will schedule a sampling event and submit results via form 43. PDC will continue to monitor monthly.
|
403005396 | Form 17 | 4/1/2022 | 4/5/2022 | FLOWING | 3 | DOWN TO 0 | GAS | 0 | NO FLOW | 1961 | 1961 | No | -- | -- | Test after DOFP. Whisper on open for 2 minutes and died. No flow for remainder of test. |
402867573 | Form 17 | 11/2/2021 | 11/10/2021 | SHUT-IN | 0 | NO FLOW | NONE | 0 | NO FLOW | 0 | 0 | No | -- | -- | Test prior to toe prep/frac. Vacuum on open for 40 seconds. |