WELL05-123-46695J Clark
13N
PDC ENERGY INC
69175
PR
2/1/2022
WATTENBERG
90750
WELD  123
NWNE 14 5N65W 6
323242
   
Search for Different Bradenhead:
County Code: Sequence Code:
 
Surface Casing Depth: 1670 ft.
View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
404595061Form 173/23/20263/25/2026PLUNGER LIFT53DOWN TO 0 WATER AND GAS0 CONTINUOUS 335330No----Remediation follow up test. 53 PSI gas and water, blew down to 0 within first few seconds, water continued for entire test. Fluid quantity insufficient to sample. Operator will monitor pressure and re-test according to bradenhead policy.
404182118Form 174/9/20254/28/2025PLUNGER LIFT46DOWN TO 0 WATER AND GAS0 CONTINUOUS 284269No----Remediation follow up test. 46 PSI gas and water, blew down to 0 within first few seconds, water continued for entire test, ~1 gal collected. Operator will schedule a sampling event and submit results via form 43. Operator will monitor pressure and re-test according to bradenhead policy.
Click for SpecificsLight2/26/20253/4/2025 12 --0 314346NoNoNo 
403885378Form 178/6/20248/12/2024PLUNGER LIFT56CONTINUOUS WATER AND LIQUID HYDROCARBON0 WHISPER 282269No----Annual Test. 56 PSI fluid flow blew down to 0 PSI in 30 minutes, ~1.25 gallons total fluid. PDC will monitor pressure and re-test according to bradenhead policy.
Click for SpecificsFull3/18/20244/3/2024 0No Flow--0No Flow284279NoNoNoAnnual Test.  0 PSI, with no pressure or flow observed for the entire 30-minute test.  PDC will monitor pressure and re-test according to bradenhead policy.
Click for SpecificsFull3/15/20233/27/2023 10Down to Zero--0No Flow220221NoNoneNoneAnnual Test. 10 PSI blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. PDC will continue to monitor monthly.
Click for SpecificsFull3/14/20224/18/2022 0No Flow--0No Flow260255NoNoNo 
Click for SpecificsFull4/12/202111/1/2021 24Gas--0Down to Zero463468NoNoneNone 
Click for SpecificsLight4/30/20205/11/2020 5 --5 780780NoNoNo 
Click for SpecificsLight10/20/20198/18/2020 0 --0 918918NoNoNo