Skip to Main Content

Incident Search

 
BradenheadView Related Related View DocsDoc
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation ID
WELL05-123-46041Postle IC
09-299HN
PDC ENERGY INC
69175
PR
4/1/2025
WATTENBERG
90750
WELD  123
SWNW 11 3N68W 6
433857
   
Search for Different Bradenhead:
County Code: Sequence Code:
 
Surface Casing Depth: 1528 ft.
View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
404265991Form 176/12/20257/2/2025GAS LIFT23CONTINUOUS WATER AND GAS1 WHISPER 374375No----Remediation follow up test. 23 PSI gas and water, blew down to in thirty minutes, water continued for entire test, ~1 gal. Operator will schedule a sampling event and submit results via form 43. Operator will monitor pressure and re-test according to bradenhead policy.
403840975Form 176/21/20246/30/2024 35DOWN TO 0 WATER AND GAS0 CONTINUOUS 340346No----Remediation follow up test. 35 PSI continuous gas and water flow blew down to 0 PSI within five minutes, continuous water flow observed throughout entire test. PDC will schedule a sampling event and submit results via form 43. PDC will monitor pressure and re-test according to bradenhead policy.
403412412Form 175/18/20235/24/2023PLUNGER LIFT82CONTINUOUS WATER AND GAS0 CONTINUOUS 282282No----Annual test. 82 PSI water and gas flow blew down to 0 PSI in 5 minutes. Water trickled for the entire test. PDC will monitor pressure and re-test according to bradenhead policy.
403263374Form 1712/15/202212/16/2022PLUNGER LIFT24CONTINUOUS WATER AND GAS0 CONTINUOUS 356358No----Abatement system follow up test. 24 PSI water and gas flow blew down to 0 PSI within first minute of test. 1 qt water at open, then steady trickle first 4 minutes of test, then steady drip for remainder of test. PDC will submit sundry with bradenhead details as soon as possible. PDC will continue to monitor monthly.
403058970Form 175/18/20225/25/2022FLOWING151DOWN TO 0 WATER H200 CONTINUOUS 895895Yes--YesTest after pressure discovery. Water on open, collected 1000mL sample. Down to 0 immediately. Intermittent trickle/drips for duration of test, produced ~2 liters total.
402867436Form 1711/5/202111/10/2021PLUNGER LIFT20DOWN TO 0 WATER H200 NO FLOW 545548No----Re-test after 10 day build up. Water on open, produced less than a quart and died. Not enough volume for sample. No flow for remainder of test.
402664684Form 174/16/20214/20/2021FLOWING84DOWN TO 0 WATER H200 CONTINUOUS 727727Yes--YesTest per NTO. Water on open, collected 1000 mL sample. BH died to trickle immediatley and turned to drips @ 15 minute mark. Made ~ 1/2 gallon total.
402302125Form 171/24/20202/3/2020FLOWING39WATER H20 --0 WATER H20 866866Yes--YesTest after 5 week blowdown and 1 week build up. 1980 mL water sample taken. Made ~ 3 quarts total.
402232183Form 1711/1/201911/6/2019FLOWING84NO FLOW --0 NO FLOW 12081209YesYes--Test per NTO. Prod and BH gas sample taken. BH died in 3 seconds.
401719296Form 177/25/20187/31/2018FLOWING32NO FLOW --0 NO FLOW 19121913No----Test taken within 30 days of DOFP. Died in 1 second.
401599190Form 174/7/20184/10/2018SHUT-IN65DOWN TO 0 --0 NO FLOW 00No----