WELL05-123-45877Pierce DE
26-054
PDC ENERGY INC
69175
TA
8/2/2019
PIERCE
69000
WELD  123
SESW 23 8N66W 6
453032
   
Search for Different Bradenhead:
County Code: Sequence Code:
 
Surface Casing Depth: 1539 ft.
View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
Click for SpecificsFull3/5/20263/16/2026 0No Flow--0No Flow00NoNoNoAnnual Test.  0 PSI, with no pressure or flow observed for the entire 30-minute test.  Operator will monitor pressure and re-test according to bradenhead policy.
404142587Form 173/17/20253/26/2025SHUT-IN12CONTINUOUS GAS0 WHISPER 00No----Annual Test. 12 PSI gas blew down to 0 PSI within thirty minutes of test, gas observed for entire test.. Operator will schedule a sampling event and submit results via form 43. Operator will monitor pressure and re-test according to bradenhead policy.
403722927Form 173/15/20243/18/2024SHUT-IN15CONTINUOUS GAS0 WHISPER 00No----Annual test. 15 PSI whisper gas blew down to 0 PSI in 30 minutes. PDC will monitor pressure and re-test according to bradenhead policy.
Click for SpecificsFull3/29/20234/10/2023 3Down to Zero--0Down to Zero00NoNoneNoneAnnual Test. 3 PSI blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. PDC will continue to monitor monthly.
Click for SpecificsFull9/29/202210/10/2022 17Down to Zero--0Down to Zero00NoNoneNone 
402679341Form 174/28/20215/4/2021SHUT-IN17DOWN TO 0 GAS0 NO FLOW 77No----Test per NTO. Gas on open, died at 9 minute mark, no flow for the remainder of the test.
402520967Form 1710/22/202010/28/2020SHUT-IN15GAS --0 NO FLOW 2121No----Test per 2020 NTO. Gas on open, down to whisper by 5 minutes mark, died by 7 minute mark. No flow for remainder of test.
402223627Form 1710/25/201910/28/2019SHUT-IN15DOWN TO 0 --0 NO FLOW 00No----Test per NTO. Blew dead through a 2" ball valve < 5 secs. BH dead
402223604Form 1710/25/201910/28/2019SHUT-IN15DOWN TO 0 --15 NO FLOW 00No----Test per NTO. Blew dead through 2 " ball valve < 5 secs. BH dead
402223588Form 1710/25/201910/28/2019SHUT-IN15DOWN TO 0 --0 NO FLOW 00Yes----Test per NTO. Blew dead through 2' ball valve < 5 secs. BH dead
401664195Form 176/6/20186/6/2018SHUT-IN0NO FLOW --0 NO FLOW 00No----Test taken after DOFP. Bradenhead Dead.
401496493Form 1712/27/20171/2/2018SHUT-IN0NO FLOW --0 NO FLOW 00No----