Skip to Main Content

Incident Search

 
BradenheadView Related Related View DocsDoc
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation ID
WELL05-123-45249ROBIN
9-17HZ
KERR MCGEE OIL & GAS ONSHORE LP
47120
PR
6/1/2022
WATTENBERG
90750
WELD  123
SESE 9 1N65W 6
441273
   
Search for Different Bradenhead:
County Code: Sequence Code:
 
Surface Casing Depth: 1888 ft.
View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
Click for SpecificsFull10/22/202411/12/2024 0No FlowNone--No Flow171171NoNN Surface Casing produced no liquid.
Click for SpecificsFull11/22/202312/11/2023Plunger Lift1WhisperNone--No Flow143139NoNN Tubing Shut in. Surface Casing produced no liquid.
Click for SpecificsFull5/17/20226/13/2022Plunger Lift0No FlowNone--No Flow-1-1NoNN Tubing and Casing dead. Surface Casing on vacuum. Surface Casing produced no liquid.
Click for SpecificsFull6/3/20217/19/2021Plunger Lift1WhisperNone--No Flow201167NoNN Tubing Shut in. Surface Casing produced no liquid.
Click for SpecificsFull10/21/202012/21/2020Plunger Lift1WHISPER ----DOWN TO 0 257225NoNoNo Surface Casing produced no liquid.
402000039Form 173/4/20194/8/2019PLUNGER LIFT6GAS --0 DOWN TO 0 18201818No----Surface casing produced no fluids. Well shut in for 15 minutes ended with 0 PSI.
401967133Form 173/4/20193/11/2019PLUNGER LIFT6GAS --0 DOWN TO 0 18201818No----Surface casing produced no fluid. Well shut in for 15min ended with no psi.
401769254Form 179/13/20189/20/2018 1WHISPER --0 DOWN TO 0 00No----Surface casing produced no fluids. Surface casing shut in for 15 min ended with 0 PSI.
401645660Form 175/9/20185/18/2018PLUNGER LIFT1WHISPER --0 DOWN TO 0 11No----Surface casing produced no fluids. Surface casing shut in for 15 minutes ended with 0 PSI. Well and master shut in.
401517597Form 171/11/20181/17/2018 1WHISPER --0 DOWN TO 0 11No----Surface casing produced no fluids. Surface casing shut in for 15 minutes ended with 0 PSI. Master valve was shut. Post drill Form 17