WELL05-123-44992Raindance FD
20-242HN
PDC ENERGY INC
69175
PR
6/15/2019
WATTENBERG
90750
WINDSOR/WELD  123
NENE 30 6N67W 6
427917
   
Search for Different Bradenhead:
County Code: Sequence Code:
 
Surface Casing Depth: 1543 ft.
View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
Click for SpecificsFull5/14/20245/30/2024 0Down to Zero--0Down to Zero00NoNoNoAnnual Test.  0 PSI, with no pressure or flow observed for the entire 30-minute test.  PDC will monitor pressure and re-test according to bradenhead policy.
403737235Form 173/29/20244/1/2024SHUT-IN286DOWN TO 0 GAS AND LIQUID HYDROCARBON0 NO FLOW 482482No----High Pressure Verification test. 286 PSI gas and fluid blew down to 0 PSI in 20 seconds. No flow or pressure for the remainder of the test. PDC will monitor pressure and re-test according to bradenhead policy.
403550709Form 1710/4/202310/5/2023GAS LIFT241CONTINUOUS GAS0 NO FLOW 416424Yes----Annual test. 241 PSI gas flow blew down to 0 PSI in 20 seconds, ~1/4 cup fluid. No flow or pressure for remainder of test. Well currently on abatement, shut for 48 hours prior to test. PDC will schedule a sampling event and submit results via form 43. PDC will monitor pressure and re-test according to bradenhead policy.
403277899Form 1712/28/20221/3/2023PLUNGER LIFT22DOWN TO 0 GAS0 NO FLOW 445445No----Abatement system follow up test. 22 PSI gas flow blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. PDC will submit sundry with bradenhead details as soon as possible. PDC will continue to monitor monthly.
403051761Form 175/12/20225/17/2022FLOWING208DOWN TO 0 GAS0 NO FLOW 500501No----Failed Retest. Puff on open, died instantly. Water drips at 5 minutes, died at 15 minute mark. Produced about 1/8 cup water, not enough volume to sample.
Click for SpecificsLight11/3/202111/15/2021Flowing0 --0 568568NoNoNoTest per NTO. Dead at open.
402548501Form 1712/1/202012/8/2020FLOWING122DOWN TO 0 GAS0 NO FLOW 488488No----Test per NTO. Gas for 2 seconds at open then dead.
402239448Form 1711/7/201911/14/2019FLOWING42DOWN TO 0 --0 NO FLOW 889899No----Test after DOFP. Delay due to continuous surface operations. Blew dead < 15 secs. BH dead.
401989589Form 173/28/20193/29/2019SHUT-IN98NO FLOW --0 NO FLOW 00No----Test before frac. Blew down in 5 seconds. Unable to collect gas sample at this time.
401668298Form 176/1/20186/8/2018SHUT-IN115WHISPER --0 WHISPER 00Yes----Second Test, six months after rig release. Blew down in less than 1 second. Well not completed.