Skip to Main Content

Incident Search

 
BradenheadView Related Related View DocsDoc
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation ID
WELL05-123-44859Geib
26W-214
PDC ENERGY INC
69175
PR
3/19/2019
WATTENBERG
90750
WELD  123
NENE 26 5N65W 6
450654
   
Search for Different Bradenhead:
County Code: Sequence Code:
 
Surface Casing Depth: 1625 ft.
View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
404220332Form 175/16/20255/28/2025PLUNGER LIFT30CONTINUOUS WATER H200 NO FLOW 482474No----Annual Test. 30 PSI blew down to 0 PSI within ten minutes of test. No pressure or flow observed for the remainder of the test. Operator will monitor pressure and re-test according to bradenhead policy.
403867502Form 177/23/20247/26/2024PLUNGER LIFT45CONTINUOUS WATER AND GAS0 CONTINUOUS 523523No----Annual test. 45 PSI water and gas flow blew down to 0 PSI in seconds, water continued to trickle for entire test. PDC will monitor pressure and re-test according to bradenhead policy.
Click for SpecificsFull9/20/20239/25/2023Plunger Lift15Down to Zero--0Down to Zero433429NoNoNoAnnual Test. 15 PSI blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. PDC will monitor pressure and re-test according to bradenhead policy.
Click for SpecificsFull6/20/20227/6/2022 19Down to Zero--0Down to Zero320371NoNoneNone 
Click for SpecificsFull7/20/202111/1/2021 12Whisper (very low flow)--0No Flow518516NoNoneNone 
402447735Form 173/12/20207/21/2020 71CONTINUOUS --0 DOWN TO 0 823824No----6 month follow-up test post abatement system install. PDC will continue to monitor pressure and report any increase in pressure to COGCC.
402034568Form 174/25/20195/7/2019FLOWING604CONTINUOUS --3 WHISPER 27172716Yes----604 PSI blew down to 3 PSI instantly slight whisper throughout the test, PDC has collected a bradenhead and production sample and will submit via form 43 when available. PDC will follow up with a sundry proposing a remediation plan for bradenhead pressure.