Skip to Main Content

Incident Search

 
BradenheadView Related Related View DocsDoc
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation ID
WELL05-123-43895Cecils Kersey Farm
17B-214
PDC ENERGY INC
69175
PR
9/29/2017
WATTENBERG
90750
KERSEY/WELD  123
NWSW 17 5N64W 6
445139
   
Search for Different Bradenhead:
County Code: Sequence Code:
 
Surface Casing Depth: 1630 ft.
View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
Click for SpecificsFull5/17/20245/30/2024 0Down to Zero--0Down to Zero245249NoNoNoAnnual Test.  0 PSI, with no pressure or flow observed for the entire 30-minute test.  PDC will monitor pressure and re-test according to bradenhead policy.
Click for SpecificsFull5/1/20235/8/2023 2Down to Zero--0No Flow296288NoNoneNoneAnnual Test. 2 PSI blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. PDC will monitor pressure and re-test according to bradenhead policy.
Click for SpecificsFull5/26/20226/13/2022 0No Flow--0No Flow269261NoNoneNone 
402848478Form 1710/19/202110/21/2021PLUNGER LIFT0NO FLOW --0 NO FLOW 368368No----Abatement system follow up test. No pressure or flow observed. PDC will submit sundry with bradenhead details as soon as possible. PDC will continue to monitor monthly.
402735499Form 171/28/20217/1/2021FLOWING108CONTINUOUS GAS0 NO FLOW 443455No----Post-Production - Monthly Follow-up. 108 PSI blew down to 0 PSI within thirty minutes. Slight gas flow observed for first ten minutes. PDC will schedule a sampling event and submit results via form 43 as well as a remediation plan via sundry as soon as possible.
Click for SpecificsLight7/12/202012/3/2020 15 --0No Flow392392NoNoNo 
Click for SpecificsLight6/13/20198/18/2020 23 --0 633633NoNoNo 
401440720Form 1710/15/201710/25/2017FLOWING660DOWN TO 0 --0 NO FLOW 27412741Yes----Post Production Test, blew down within 30 seconds of test. Sample collected, requested 14 day blowdown period.
401347729Form 177/14/20177/19/2017SHUT-IN550DOWN TO 0 --0 NO FLOW 00No----Pre Completion Test initial pressure 550 PSI BLEED TO 0 PSI WITHIN seconds no flow for duration of test
401327814Form 175/15/20176/29/2017SHUT-IN650DOWN TO 0 --0 NO FLOW 00No----Pre Completion test. Initial pressure was 650 PSI, instantly blew down within first minute of test to 0 PSI. No pressure for remainder of test. Attempted to collect sample but were unable to due instant blow down.