Skip to Main Content

Incident Search

 
BradenheadView Related Related View DocsDoc
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation ID
WELL05-123-43564Wacker
10F-302
PDC ENERGY INC
69175
PR
10/1/2023
WATTENBERG
90750
WELD  123
SWNW 10 5N64W 6
323125
   
Search for Different Bradenhead:
County Code: Sequence Code:
 
Surface Casing Depth: 1672 ft.
View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
403789144Form 175/9/20245/14/2024PLUNGER LIFT59WHISPER GAS0 WHISPER 257258No----Annual test. 59 PSI continuous whisper gas blew down to 0 PSI in 30 minutes. PDC will monitor pressure and re-test according to bradenhead policy.
403475374Form 177/24/20237/25/2023PLUNGER LIFT68CONTINUOUS WATER AND GAS0 NO FLOW 353351No----Abatement System Follow-Up test. 68 PSI water and gas flow blew down to 0 PSI in 5 minutes. No flow or pressure for the remainder of the test. PDC will monitor pressure and re-test according to bradenhead policy.
403411480Form 175/23/20235/24/2023SHUT-IN106CONTINUOUS WATER AND GASTSTM CONTINUOUS 348348Yes----Annual test. 106 PSI water and gas flow blew down to almost 0 PSI in 30 minutes. PDC will collect a sample and submit results via form 43. PDC will monitor pressure and re-test according to bradenhead policy.
Click for SpecificsFull8/31/20229/6/2022 5Down to Zero--0Down to Zero303303NoNoneNone 
Click for SpecificsFull3/9/202111/1/2021 0No Flow--0No Flow348355NoNoneNone 
402446558Form 173/14/20207/20/2020 96MUD --0 NO FLOW 501507No----6 month follow-up test post abatement system install. PDC will continue to monitor pressure and report any increase in pressure to COGCC.
402229140Form 1710/11/201911/1/2019FLOWING206WHISPER --0 NO FLOW 798798YesYes--Annual TEst, 206 PSI slight whisper blew down to 0 PSI within first minute of test. No pressure or fluid was observed for the remainder of the test. PDC has collected a sample and will submit results via form 43. PDC has submitted a remediation plan via sundry.