| Click for Specifics | Light | 3/2/2025 | 4/14/2025 | | 0 | | -- | 0 | | 435 | 435 | No | No | No | |
| Click for Specifics | Light | 3/23/2024 | 4/23/2024 | | 20 | | -- | 0 | | 739 | 741 | No | No | No | |
| Click for Specifics | Light | 3/7/2023 | 4/10/2023 | Plunger Lift | 23 | | -- | 0 | | 670 | 670 | No | No | No | |
| Click for Specifics | Light | 3/18/2022 | 4/18/2022 | Flowing | 24 | | -- | 0 | | 598 | 597 | No | No | No | |
| Click for Specifics | Full | 1/27/2021 | 2/16/2021 | | 27 | CONTINUOUS | -- | 0 | NO FLOW | 843 | 855 | No | No | No | Surface casing pressure blew down to 0 psi in 3 minutes, produced only gas.
|
| Click for Specifics | Full | 3/25/2020 | 4/6/2020 | | 32 | DOWN TO 0 | -- | 0 | NO FLOW | 619 | 620 | No | No | No | Surface casing pressure blew down to 0 psi in 30 seconds, produced only gas. |
| 402008143 | Form 17 | 4/15/2019 | 4/15/2019 | FLOWING | 27 | DOWN TO 0 | -- | 0 | NO FLOW | 931 | 931 | No | -- | -- | Surface casing blew down to 0 psi in 12 seconds, only gas. |
| 401880166 | Form 17 | 12/15/2018 | 12/18/2018 | CLOCK/INTERMITTER | 41 | GAS | -- | 0 | NO FLOW | 724 | 724 | Yes | -- | -- | blew down immediately to zero, no flow throughout test |
| 401779495 | Form 17 | 8/18/2018 | 10/1/2018 | FLOWING | 55 | WHISPER | -- | 0 | WHISPER | 260 | 259 | No | -- | -- | surface csg didnt blow down completely, but didn't have enough to register pressure on digital or hard gauge. |
| 401661634 | Form 17 | 6/1/2018 | 6/4/2018 | FLOWING | 67 | DOWN TO 0 | -- | 0 | NO FLOW | 316 | 316 | No | -- | -- | |