WELL05-123-42067Sater
19E-203
PDC ENERGY INC
69175
TA
10/1/2025
WATTENBERG
90750
WELD  123
NWNW 19 4N63W 6
442952
   
Search for Different Bradenhead:
County Code: Sequence Code:
 
Surface Casing Depth: 1619 ft.
View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
404477118Form 1712/8/202512/17/2025SHUT-IN0NO FLOW NONE0 NO FLOW 00No---- 
404450636Form 1710/22/202511/25/2025SHUT-IN16CONTINUOUS GAS0 NO FLOW 00No---- 
404330015Form 178/6/20258/26/2025SHUT-IN95CONTINUOUS GAS0 NO FLOW 00No----Abatement System Follow-up Test. 95 PSI gas blew down to 0 PSI within five minutes of test. No pressure or flow observed for the remainder of test. Operator will monitor pressure and re-test according to bradenhead policy.
404285916Form 176/30/20257/18/2025SHUT-IN335DOWN TO 0 GAS0 WHISPER 210210No----Pre-P&A. 335 PSI gas flow blew down to 0 PSI within first few seconds, whisper gas continued for entire test. Operator will schedule a sampling event and submit results via form 43.
404098652Form 172/6/20252/18/2025SHUT-IN303CONTINUOUS GAS0 WHISPER 00No----Engineering Ad Hoc test. 303 PSI gas blew down to 1 PSI in thirty minutes. Gas was present the entire test. Operator will schedule a sampling event and submit results via form 43. Operator will continue to monitor monthly.
Click for SpecificsFull4/29/20245/6/2024 0No Flow--0No Flow454454NoNoNoAnnual Test.  0 PSI, with no pressure or flow observed for the entire 30-minute test.  PDC will monitor pressure and re-test according to bradenhead policy.
Click for SpecificsFull4/22/20244/30/2024 0No Flow--0No Flow545545NoNoNo 
Click for SpecificsFull4/18/20234/24/2023 0Down to Zero--0Down to Zero199198NoNoneNoneAnnual Test. 0 PSI, with no pressure or flow observed for the entire 30-minute test. PDC will continue to monitor monthly.
403135415Form 178/12/20228/15/2022PLUNGER LIFT67DOWN TO 0 GAS0 NO FLOW 237237Yes----Annual Test, 67 PSI blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. PDC will schedule a sampling event and submit results via form 43. PDC will continue to monitor monthly.
402753459Form 175/8/20217/20/2021PLUNGER LIFT0NO FLOW --0  272272No----Annual Test, 0 psi with no flow observed for 30 minutes.
Click for SpecificsLight8/11/202012/3/2020 2 --0No Flow320320NoNoNo 
402418350Form 171/13/20206/10/2020 0NO FLOW --0  445--No----6 month follow-up test post abatement system install. PDC will continue to monitor pressure and report any increase in pressure to COGCC.
402059581Form 174/7/20195/30/2019FLOWING200DOWN TO 0 --0 NO FLOW 384384No----Annual Test, 200 PSI blew down to 0 PSI instantly 0 PSI after 30 min. A followup sundry porposing a remediation plan will be submitted within 10 days.