| 404597365 | Form 17 | 3/25/2026 | 3/26/2026 | SHUT-IN | 62 | CONTINUOUS | GAS | 0 | NO FLOW | 62 | 0 | No | -- | -- | Annual Test. 62 PSI blew down to 0 PSI within ten minutes of test. No pressure or flow observed for the remainder of the test. Operator will monitor pressure and re-test according to bradenhead policy. |
| 404413418 | Form 17 | 10/21/2025 | 10/29/2025 | SHUT-IN | 45 | CONTINUOUS | GAS | 0 | NO FLOW | 45 | 0 | No | -- | -- | Remediation follow up test. 45 PSI whisper blew down to 0 PSI within ten minutes of test. No pressure or flow observed for the remainder of the test. Operator will monitor pressure and re-test according to bradenhead policy |
| 404382751 | Form 17 | 10/1/2025 | 10/7/2025 | SHUT-IN | 37 | CONTINUOUS | GAS | 0 | NO FLOW | 1 | 1 | No | -- | -- | Remediation follow up test. 37 PSI blew down to 0 PSI within five minutes of test. No pressure or flow observed for the remainder of the test. Operator will monitor pressure and re-test according to bradenhead policy. |
| 404351625 | Form 17 | 8/28/2025 | 9/11/2025 | SHUT-IN | 34 | CONTINUOUS | GAS | 0 | NO FLOW | 600 | 600 | No | -- | -- | Pre-P&A. 34 PSI blew down to 0 PSI within ten minutes of test. No pressure or flow observed for the remainder of the test. |
| 404180170 | Form 17 | 4/23/2025 | 4/25/2025 | SHUT-IN | 65 | DOWN TO 0 | GAS | 0 | NO FLOW | 0 | 0 | No | -- | -- | Annual Test. 65 PSI blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. Operator will monitor pressure and re-test according to bradenhead policy. |
| Click for Specifics | Full | 10/9/2024 | 10/22/2024 | | 25 | Down to Zero | -- | 0 | No Flow | 358 | 358 | No | No | No | Annual Test. 25 PSI blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. PDC will monitor pressure and re-test according to bradenhead policy. |
| Click for Specifics | Full | 4/22/2024 | 4/30/2024 | | 34 | Down to Zero | -- | 0 | No Flow | 357 | 357 | No | No | No | |
| 403421833 | Form 17 | 6/1/2023 | 6/2/2023 | PLUNGER LIFT | 96 | CONTINUOUS | GAS | 0 | NO FLOW | 221 | 214 | Yes | -- | -- | Automation Alert Follow-Up. 96 PSI gas flow blew down to 0 PSI in 5 minutes with no flow or pressure for the remainder of the test. PDC will schedule a sampling event and submit results via form 43. PDC will monitor pressure and re-test according to bradenhead policy. |
| Click for Specifics | Full | 4/7/2023 | 4/17/2023 | | 16 | Down to Zero | -- | 0 | Down to Zero | 245 | 245 | No | None | None | |
| Click for Specifics | Full | 8/12/2022 | 9/6/2022 | | 0 | No Flow | -- | 0 | No Flow | 222 | 221 | No | None | None | |
| Click for Specifics | Full | 6/9/2021 | 11/1/2021 | | 0 | No Flow | -- | 0 | No Flow | 282 | 282 | No | None | None | |
| Click for Specifics | Light | 8/15/2020 | 12/14/2020 | | 0 | | -- | 0 | | 100 | 100 | No | No | No | |
| Click for Specifics | Light | 3/8/2019 | 8/18/2020 | | 6 | | -- | 0 | | 379 | 379 | No | No | No | |