Skip to Main Content

Incident Search

 
BradenheadView Related Related View DocsDoc
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation ID
WELL05-123-39347Kodak North FD
28-119HN
PDC ENERGY INC
69175
PR
3/1/2025
WATTENBERG
90750
WELD  123
SENW 26 6N67W 6
333035
   
Search for Different Bradenhead:
County Code: Sequence Code:
 
Surface Casing Depth: 1053 ft.
View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
Click for SpecificsFull2/11/20262/16/2026 0No Flow--0No Flow395395NoNoNoAnnual Test.  0 PSI, with no pressure or flow observed for the entire 30-minute test.  Operator will monitor pressure and re-test according to bradenhead policy.
404147308Form 173/18/20253/31/2025PLUNGER LIFT9DOWN TO 0 WATER AND GAS0 CONTINUOUS 527533No----Remediation follow up test. 9 PSI gas and water, blew down to 0 within first few seconds, water continued for entire test, ~1/2 gal. Operator will schedule a sampling event and submit results via form 43. Operator will monitor pressure and re-test according to bradenhead policy.
404111034Form 172/21/20252/28/2025SHUT-IN14CONTINUOUS GAS0 WHISPER 752752No----Annual test. 14 PSI gas flow blew down to 0 PSI in thirty minutes, gas switched to gas and water and remained through entire test. PDC will monitor pressure and re-test according to bradenhead policy.
403692904Form 172/13/20242/20/2024SHUT-IN21CONTINUOUS GAS AND LIQUID HYDROCARBON0 CONTINUOUS 645645No----Annual test. 21 PSI gas and fluid blew down to 0 PSI in 5 minutes. Green fluid trickle/dripped for entire test, ~1 quart total fluid. PDC will monitor pressure and re-test according to bradenhead policy.
403426244Form 175/31/20236/7/2023PLUNGER LIFT10CONTINUOUS WATER AND GAS0 DOWN TO 0 307303No----Annual Test. 10 PSI blew down to 0 PSI within first 40 seconds of test. ~1 qt fluid at open, intermittent fluid for remainder of test. PDC will monitor pressure and re-test according to bradenhead policy.
403261564Form 1710/3/202212/15/2022PLUNGER LIFT50DOWN TO 0 GAS AND LIQUID HYDROCARBON0 NO FLOW 365368Yes----Automation Alert Follow-up. 50 PSI gas and fluid blew down to 0 PSI within first 5 minutes of test. 1/2 gallon fluid at open. No pressure or flow observed for the remainder of the test. PDC will continue to monitor monthly.
402867678Form 1711/9/202111/10/2021PLUNGER LIFT41DOWN TO 0 WATER H200 NO FLOW 254255No----Re-test after 68 day buildup. Water on open, produced ~ 1/4 cup and died. No flow for remainder of test. Not enough volume to sample
402719568Form 176/9/20216/15/2021FLOWING55CONTINUOUS WATER H200 CONTINUOUS 385391No----Test per NTO. Water at open. Water for entire test. Did not make enough for sample.
402538628Form 1711/19/202011/23/2020FLOWING39CONTINUOUS WATER H200 NO FLOW 427428No----Test per 2020 NTO. Made ~ 1 cup of water on open and died. Unable to collect water sample due to lack of volume.
402209216Form 1710/11/201910/14/2019SHUT-IN23DOWN TO 0 --0 NO FLOW 12161216No----Test per NTO. Produced 5 cups of water then died < 30 secs. BH dead.