| 404332959 | Form 17 | 7/31/2025 | 8/27/2025 | SHUT-IN | 0 | NO FLOW | NONE | 0 | NO FLOW | 400 | 400 | No | -- | -- | Pre-P&A. 0 PSI, with no flow observed for 30 minutes.
|
| Click for Specifics | Light | 4/6/2025 | 4/14/2025 | | 1 | | -- | 0 | | 248 | 248 | No | No | No | |
| Click for Specifics | Full | 5/7/2024 | 5/21/2024 | | 0 | No Flow | -- | 0 | No Flow | 200 | 200 | No | No | No | Annual Test. 0 PSI, with no pressure or flow observed for the entire 30-minute test. PDC will monitor pressure and re-test according to bradenhead policy. |
| Click for Specifics | Full | 8/4/2023 | 8/14/2023 | Plunger Lift | 0 | No Flow | -- | 0 | No Flow | 390 | 391 | No | No | No | Annual Test. 0 PSI, with no pressure or flow observed for the entire 30-minute test. PDC will monitor pressure and re-test according to bradenhead policy. |
| 402992085 | Form 17 | 3/15/2022 | 3/22/2022 | SHUT-IN | 0 | NO FLOW | NONE | 0 | NO FLOW | 704 | 703 | No | -- | -- | Test per NTO. BH dead. |
| 402712465 | Form 17 | 6/7/2021 | 6/9/2021 | SHUT-IN | 0 | WHISPER | GAS | 0 | NO FLOW | 652 | 649 | No | -- | -- | Test per NTO. Whisper on open for 30 seconds and died. No flow for remainder of test. |
| Click for Specifics | Light | 11/17/2020 | 12/3/2020 | Shut-In | 0 | | -- | 0 | No Flow | 602 | 606 | No | No | No | Test per NTO Whisper at open for 10 seconds then dead |
| 402239791 | Form 17 | 11/12/2019 | 11/14/2019 | FLOWING | 0 | NO FLOW | -- | 0 | NO FLOW | 633 | 640 | No | -- | -- | Test per NTO. BH dead |