| 404130358 | Form 17 | 3/11/2025 | 3/17/2025 | SHUT-IN | 0 | WHISPER | WATER AND GAS | 0 | NO FLOW | 260 | 260 | No | -- | -- | Pre-P&A. 0 PSI, whisper water and gas observed for first few seconds of test. No pressure or flow observed for the remainder of the test. |
| Click for Specifics | Full | 5/8/2024 | 5/21/2024 | | 0 | No Flow | -- | 0 | No Flow | 0 | 0 | No | No | No | Annual Test. 0 PSI, with no pressure or flow observed for the entire 30-minute test. PDC will monitor pressure and re-test according to bradenhead policy. |
| Click for Specifics | Full | 5/25/2023 | 6/5/2023 | Shut-In | 1 | Down to Zero | -- | 0 | Down to Zero | 548 | 548 | No | None | None | |
| 403025366 | Form 17 | 4/14/2022 | 4/24/2022 | SHUT-IN | 0 | WHISPER | GAS | 0 | NO FLOW | 585 | 585 | No | -- | -- | Test per NTO. Whisper on open for 45 seconds and died. No flow for remainder of test. |
| 402711820 | Form 17 | 6/2/2021 | 6/8/2021 | SHUT-IN | 0 | WHISPER | GAS | 0 | NO FLOW | 653 | 653 | No | -- | -- | Test per NTO. Whisper on open for 30 seconds and died. No flow for remainder of test. |
| Click for Specifics | Light | 11/13/2020 | 12/3/2020 | Shut-In | 0 | | -- | 0 | No Flow | 717 | 718 | No | No | No | Test per NTO. Whisper at open for 1 minute then dead. |
| 402232122 | Form 17 | 10/30/2019 | 11/6/2019 | SHUT-IN | 0 | NO FLOW | -- | 0 | NO FLOW | 786 | 786 | No | -- | -- | Test per NTO. BH dead |