| 402166381 | Form 17 | 8/30/2019 | 9/5/2019 | PLUNGER LIFT | 19 | GAS | -- | 1 | WHISPER | 13 | 0 | No | -- | -- | Surface casing produced no fluids. 15 minute shut in resultsin 4 psi. 30 minute blow down results in whisper. Tubing shut in. |
| 401914204 | Form 17 | 1/18/2019 | 1/23/2019 | | 82 | GAS | -- | 17 | CONTINUOUS | 1402 | 1402 | No | -- | -- | Surface casing produced oil. Stopped test after first 30 min. Surface casing shut in for 15 min ended with 22 PSI. Well and master were shut in. |
| 401838108 | Form 17 | 11/8/2018 | 11/14/2018 | | 76 | GAS | -- | 40 | | 1395 | -- | No | -- | -- | STOPPED TEST AFTER SURFACE CASING PRODUCED OIL. SURFACE CASING SHUT-IN FOR 15 MIN; ENDED WITH 46 PSI. WELL AND MASTER VALVE SHUT-IN. |
| 400811467 | Form 17 | 3/2/2015 | 3/19/2015 | PLUNGER LIFT | 114 | GAS | -- | 24 | NO FLOW | 604 | 606 | No | -- | -- | SURFACE CASING PRODUCED 15 GALLONS OF OIL. MONITORED SURFACE CASING AN EXTRA 30 MINUTES, PRESSURE BLEW-DOWN TO
12 PSI. SHUT-IN SURFACE CASING FOR 15 MINUTES, PRESSURE BUILT UP TO 19 PSI. |
| 400803237 | Form 17 | 2/13/2015 | 3/4/2015 | PLUNGER LIFT | 234 | GAS | -- | 51 | GAS | 590 | 591 | No | -- | -- | SURFACE CASING PRODUCED NO FLUIDS DURING TEST. MONITORED THE SURFACE CASING AN EXTRA 30 MINUTES, PRESSURE ENDED AT 25 PSI. SHUT THE SURFACE CASING IN FOR 15 MINUTES, PRESSURE BUILT-UP TO 33 PSI. |