WELL05-123-21976SOUTH LOST CREEK
8
O'BRIEN ENERGY RESOURCES CORP
65110
PR
12/1/2021
LOST CREEK
51600
WELD  123
SWSW 28 3N62W 6
332212
   
Search for Different Bradenhead:
County Code: Sequence Code:
 
Surface Casing Depth: 596 ft.
View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
404494609Form 1712/26/20251/5/2026SHUT-IN0NO FLOW NONE0 NO FLOW 300260No----Each test was concluded as a good test, with no pressure anomalies. For each test the bradenhead test valve was piped to surface with a 1" riser.
403987122Form 1710/21/202411/7/2024SHUT-IN0NO FLOW NONE0 NO FLOW 300260No----Each test was concluded as a good test, with no pressure anomalies. For each test the bradenhead test valve was piped to surface with a 1" riser.
403775211Form 1712/4/20235/1/2024SHUT-IN0NO FLOW NONE0 NO FLOW 240240No----Good test, no pressure anomalies. Braden test valve piped to surface with 1" riser.
403752169Form 1712/4/20234/12/2024SHUT-IN0NO FLOW NONE0 NO FLOW 00No----Good test, no pressure anomalies. Braden test valve piped to surface with 1" riser.
403775198Form 1712/1/20225/1/2024SHUT-IN0NO FLOW NONE0 NO FLOW 230230No----Good test, no pressure anomalies. Braden test valve piped to surface with 1" riser.
403752157Form 1712/1/20224/12/2024SHUT-IN0NO FLOW NONE0 NO FLOW 00No----Good test, no pressure anomalies. Braden test valve piped to surface with 1" riser.
402885495Form 1711/27/202112/2/2021SHUT-IN0NO FLOW NONE0 NO FLOW 250250No----Good test, no pressure anomolies. Braden test valve piped to surface with 1" riser
403256946Form 1712/9/202012/12/2022SHUT-IN0NO FLOW NONE0 NO FLOW 215215No----Good test, no pressure anomalies. Braden test valve piped to surface with 1" riser
402556279Form 1712/1/202012/17/2020SHUT-IN0NO FLOW NONE0 NO FLOW 00No----Good test, no pressure anomalies. Braden test valve piped to surface with 1" riser.
402297110Form 171/28/20201/29/2020SHUT-IN0NO FLOW --0 NO FLOW 00No----Good test, no pressure anomolies. Braden test valve piped to surface with 1" riser.
402297064Form 171/28/20201/29/2020SHUT-IN0NO FLOW --0 NO FLOW 00No----Good test, no pressure anomolies. Braden test valve piped to surface with 1" riser.