| 404329511 | Form 17 | 8/12/2025 | 8/25/2025 | SHUT-IN | 37 | DOWN TO 0 | WATER AND GAS | 0 | CONTINUOUS | 0 | 0 | No | -- | -- | Remediation follow up test. 37 PSI gas and water, blew down to 0 within first few seconds, water continued for entire test. Operator will schedule a sampling event and submit results via form 43. Operator will monitor pressure and re-test according to bradenhead policy. |
| Click for Specifics | Light | 7/24/2025 | 8/19/2025 | | 5 | | -- | 0 | | 650 | 650 | No | No | No | |
| 403762837 | Form 17 | 4/17/2024 | 4/22/2024 | SHUT-IN | 5 | WHISPER | WATER AND GAS | 0 | WHISPER | 0 | 0 | No | -- | -- | Annual test. 5 PSI blew down to 0 PSI in seconds, continuous trickle with fluid and gas surges for entire test, ~15 gallons total fluid. PDC will monitor pressure and re-test according to bradenhead policy. |
| 403368392 | Form 17 | 3/30/2023 | 4/7/2023 | SHUT-IN | 14 | DOWN TO 0 | WATER AND GAS | 0 | DOWN TO 0 | 628 | 628 | No | -- | -- | Annual Test. 14 PSI gas and water flow blew down to 0 PSI within first few seconds of test. Steady stream of fluid at open lasting 40 seconds, then steady dripping from 4 minutes until 22 minutes, then on and off dripping for remainder of the test. PDC will continue to monitor monthly. |
| 403196590 | Form 17 | 10/12/2022 | 10/13/2022 | SHUT-IN | 38 | DOWN TO 0 | GAS | 0 | NO FLOW | 620 | 620 | Yes | -- | -- | Annual Test. 38 PSI gas flow blew down to 0 PSI within first minute of test. No pressure or flow observed for the remainder of the test. PDC will schedule a sampling event and submit results via form 43 as well as a remediation plan via sundry as soon as possible. PDC will continue to monitor monthly. |
| Click for Specifics | Full | 10/22/2021 | 11/1/2021 | | 30 | Down to Zero | -- | 0 | No Flow | 600 | 600 | No | None | None | |
| Click for Specifics | Light | 10/9/2020 | 12/3/2020 | | 30 | | -- | 0 | No Flow | 600 | 600 | No | No | No | |
| 402415887 | Form 17 | 6/11/2019 | 6/8/2020 | FLOWING | 35 | DOWN TO 0 | -- | 0 | NO FLOW | 539 | 539 | No | -- | -- | Annual Test 2019. This well was operated by SRC at the time the test was conducted, this form is being submitted to correct upload issues that were required for 2019 testing. PDC will re-test and if possible, collect a sample and submit results when available. 35 PSI blew down to 0 PSI at the end of the 30 min test |